Compression load cell COL2


Download PDF

Compression load cells for weighing platforms, silos, hoppers etc..

Compression load cell

Upon request with ATEX or IECEx certification

Omologated C4


Zoom Click to enlarge image

Compression load cell COL2 Compression load cell COL2 Schema
ATEX IECEX OIML Analog Output

Technical Specifications

MaterialSteel
Nominal load18, 20, 25, 30, 35 t
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageVcc 15 Max
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,03 % F.S.
Hysteresis0,03 % F.S.
Reapeatability0,03 % F.S.
Input resistance800-805 ohm
Output resistance700-705 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,03 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4 / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 68
Standard cable length16 - 20 m – 6 x 0,30 (shield not connected to the load cell body)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeCABLE 6C R6 PVC 6X0,30
Length16 - 20 m (body lead cell not connected shield)
Green+ IN
Black- IN
Blue+ REF
Yellow- REF
Red+ OUT
White- OUT

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means